Timer Switches(Din Rail Type) MST181º C
Contact capacity: AC110V, 220-240V 16A
Full timing range: 24h
Contact resistance: ≤50mΩ
Insulation resistance: ≥100MΩ
Coil ...
Residual Current Circuit Breaker (FSL1-63):
Rated voltage Un: 230V and 230/400V
Rated current (A): 16A .25A. 32A.40A.63A
Rated frequency: 50Hz/60Hz
Rated breaking capacity: ...
Be suitalbe for RCCB etc series Residual Current Circuit Breaker products Application scope.
Rated voltage Un: 230V and 230/400V
Rated current In: 16A. 25A. 32A. 40A. 63A
Rated frequency: 50Hz/60Hz
Rated breaking capacity: 6KA,
Energy limiting class: 3
Rated fault ...
Rated voltage Un: 230V 230/400V
Rated current In: 6-63A
Rated frequency: 50Hz /60Hz
Rated breaking capacity: 6KA, 10KA
Energy limiting class: 3
Tripping characteristic: B. ...
Rated voltage Un: 230V and 230/400V
Rated current In: 6A. 10A. 13A. 16A. 25A, 32A. 40A
Rated frequency: 50Hz/60Hz
Rated breaking capacity: 6KA,
Energy limiting class: 3
Rated ...
Residual Current Circuit Breaker (FSL1-63):
Rated voltage Un: 230V and 230/400V
Rated current (A): 16A. 25A. 32A. 40A. 63A
Rated frequency: 50Hz/60Hz
Rated breaking ...
Rated voltage Un: 230/400V
Rated current In: 6A - 32A
Rated fault current: 10mA, 30mA, 100mA, 300mA, 500mA
Type: A & AC
Rated frequency: 50Hz
Rated breaking capacity: 4.5KA ...
Rated voltage: 250V
Rated In: 20A
Rated frequency 50Hz
Contactos: 2NO
Standards EN 61095
Certidicates: RoHS, NF, CE
This product is featured as simple construction and reliable performance.
The product can output stable and reliable switch signal of "making" of breaking" without any fault ...
Self-locking Nylon Cable Self-locking Ties
Rated voltage Un 230/400V
Rated In ­ 1-63A, 63-125A
Rated frequency 50H­ Z
Rated Current (A) Rated making and breaking capacity
6, 10, 16, 20, 25, 32, 40A: 6kA
50, ...
Material: Copper
Number of pole: 1P, 2P, 3P & 4P
Rated current: 63A & 125A
Material: ABS
Type Available:
50x80, 80x80, 85x85x50, 100x100x70, 150x110x70, 150x150x70, 200x100x70, 200x155x80, 255x200x80, 300x250x120, 400x350x120, 200x150x60, 200x150x80, ...
Digital Timer Switch (MST6)
7 big buttons for easy operation
Large LCD display
24 hours and 7 days programming
8 On/Off programs, up to 128 programs in a week
Accuracy: Less ...
Rated voltage Un: 230V/240V
Rated current In: 6-32A
Rated frequency: 50Hz
Rated breaking capacity: 3KA, 4.5KA
Energy limiting class: 3
Tripping characteristic: B. C
Isolating ...
Rated voltage Un: 230V /240V
Rated current In: 6-40A
Rated frequency: 50Hz /60Hz
Rated breaking capacity: 4.5KA, 6KA
Energy limiting class: 3
Tripping characteristic: B, C ...
Residual Current Circuit Breaker (MSLN2-32):
Rated voltage Un: 230V
Rated current (A): 16A. 25A. 32A.
Rated frequency: 50Hz/60Hz
Rated breaking capacity: 3KA,
Energy ...
Low Voltage Fuse Link

The main characteristics of POPP fuse disconnectors are:

Compliance with IEC 60947-1, IEC 60947-3, UL 512 and UL 486 E.

Plastic parts are made of ...
Rated voltage Un: 230V 230/400V
Rated current In: 1-63A,
Rated frequency: 50Hz/60Hz
Rated breaking capacity: 3KA, 4.5KA
Energy limiting class: 3
Tripping characteristic: B, ...
Rated voltage Un: 230V 230/400V
Rated current In: 6-63A
Rated frequency: 50Hz /60Hz
Rated breaking capacity: 6KA, 10KA
Energy limiting class: 3
Tripping characteristic: ...
Residual Current Circuit Breaker (MSLN2-32):
Rated voltage Un: 230V
Rated current (A): 16A. 25A. 32A.
Rated frequency: 50Hz/60Hz
Rated breaking capacity: 3KA,
Energy ...
Motor Circuit Breaker MSGV2-32 are applicable to a circuit with AC voltage up to 690V and current up to 80A. It can be used to protect a three-phase cage asynchronous motor and a ...
Rated voltage Un: 230V 230/400V
Rated current In: 6-63A
Rated frequency: 50Hz /60Hz
Rated breaking capacity: 6KA, 10KA
Energy limiting class: 3
Tripping characteristic: ...
Digital Timer Switch (MST7)
Voltage Range: 180~240V 50Hz
Memory bakeup: 30days
Capacitance: Resistance Load: 16A
Consumed power<4VA
Timing Control Range: 1min~168h
Timing ...
Residual Current Circuit Breaker (MSL1-63):
Rated voltage Un: 230V and 230/400V
Rated current In: 16A. 20A, 25A. 32A. 40A. 63A
Rated frequency: 50Hz/60Hz
Rated breaking ...
Rated voltage Un: 230/400V
Rated current In: 80A, 100A, 125A
Rated fault current: 30mA, 100mA, 300mA, 500mA
Type: A & AC
Number of poles: 2P, 4P
Rated frequency: 50Hz
Rated ...
Time Switches(Plug Type) MST 63
Power supply: 220-240/50HZ Max: 3500W
24 hours and days programming
8 On/Off programs, up to 128 programs in a week.
Accuracy: less than 3 ...